Sensor Modules Cabinet; Smc10/Smc20 Status Displays - Siemens SINUMERIK 828D Series Software And Hardware Service Manual

Hide thumbs Also See for SINUMERIK 828D Series:
Table of Contents

Advertisement

Service cases - hardware

4.16 Sensor Modules Cabinet

4.16
Sensor Modules Cabinet
4.16.1

SMC10/SMC20 status displays

Status displays
Sensor Modules Cabinet-Mounted SMC10 and SMC20 have the following status displays,
which provide information about the module state:
LED
Color
RDY
-
Green
Orange
Red
Green/red
Green/orange or
red/orange
202
State
Description, cause
OFF
Electronics power supply is missing or outside
permissible tolerance range.
Continuous light
The component is ready for operation and cy‐
clic DRIVE-CLiQ communication is taking
place.
Continuous light
DRIVE-CLiQ communication is being estab‐
lished.
Continuous light
This component has at least one fault.
Note:
The LED is controlled irrespective of the corre‐
sponding messages being reconfigured.
Flashes at
Firmware is being downloaded.
0.5 Hz
Flashes at 2 Hz
Firmware download has been completed.
Wait for POWER ON
Flashing
Component recognition via LED is activated
(p0144)
Note:
Both options depend on the LED status when
module recognition is activated via p0144 = 1.
Remedy
Remove and acknowl‐
edge fault.
Carry out a POWER ON.
Software and hardware
Service Manual, 08/2018, 6FC5397-5DP40-6BA1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d ppu 27.4 seriesSinumerik 828d ppu 290.4

Table of Contents