Example: Single-Channel, Failsafe Input Device, Without Test Pulse - Pilz PSS Series Operating Manual

Safety systems; units with two safetybus p interfaces
Hide thumbs Also See for PSS Series:
Table of Contents

Advertisement

Example: Single-channel, failsafe input device, without test pulse

Features:
• The input device must be approved for failsafe applications.
• Please read the instructions provided with the input device.
CAUTION!
A short circuit in the cable between the input device and input with the 24
VDC line or between adjacent inputs will not be detected. Depending on
the type of input device connected, this could create a risk to both
personnel and machinery (e.g. E-STOP). Always ensure that the unit is
suitably wired to eliminate the risk of short circuits.
Please ensure safety regulations and EMC guidelines are met!
Operating Manual: PSS SB 3006-3 Series
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
X1
0 V
T 0
T 1
I 0.0
I 0.1
I 0.2
I 0.3
I 0.4
I 0.5
L+
24 V DC
L-
Single-channel, failsafe
input device
7-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pss sb2 3006-3 cn-aPss sb2 3006-3 dn-sPss sb 3006-3 seriesPss sb2 3006-3 eth-2Pss sb2 3006-3 eth-2 dp-sPss sb2 3006-3 eth-2 ibs-s ... Show all