4.3 Electric connection

The power supply of the heat pump must pass via a protection facility and circuit-breaker (not supplied) in
compliance with applicable standards and regulations.
The appliance is foreseen for connection to the mains circuit with TT and TN.S neutral connection (according
to NF C 15-100).
• Supply cable section :
- Edenpac 6:
- Edenpac 5:
- Edenpac 3:
- Edenpac 4:
- Edenpac 3 :
- Edenpac 2 :
* This section is indicative and must be checked and adapted, if necessary, according to installation conditions .
Electrical protection: circuit breaker
protection system by 30 mA differential on the incoming supply side (
In single phase 230V 50Hz with neutral + phase + earth
Note:
• The acceptable voltage variation during operation is ± 10%
• The cable ways and ducts must be fastened.
• Only use cable suitable for outdoor use.
• Use the packing glands and cable inlets to feed the cables into the unit.
• Possibility to connect a control device
-without polarity 230V -50Hz- between terminals 1-2
• Possibility to connect an –exterior- fault indicator of 230V-50Hz between terminals 0 and 4
=> refer to the electrical wiring diagram below.
• Possibility of creating a warning signal (terminals 5 and 6) to control the filter pump if required by the
temperature conditions
order to measure the true pool water temperature)
free contact
(I max. = 5 A at 230Vac with a resistive load)
=> refer to the electrical wiring diagram below
When these electrical connections have been made, your unit automatically controls the pool filter system and ensures the water
temperature remains correct, day and night
Connection of the following optional extras: heating priority, remote On/Off, machine fault indication.
Terminal rail in
heat pump
Independent cable
5 x 2.5 mm² *
(three-phase 400V/3N/50Hz)
5 x 2.5 mm² *
(three-phase 400V/3N/50Hz)
5 x 2.5 mm² *
(three-phase 400V/3N/50Hz)
3 x 6 mm² *
(single-phase 230V/1/50Hz)
3 x 4 mm² *
(single-phase 230V/1/50Hz)
3 x 2.5 mm² *
(single-phase 230V/1/50Hz)
Configuration of supply terminal
Factory-fitted shunt
(remote On/Off)
(except in the case of heating, a 5-minute filter operating cycle every hour will be respected in
Filter timer
Phase
or
Fault indicator 230 Vac
Remote On/Off switch
** protection:
or fuse
(curve D)
(Am)
In three-phase 400V 50Hz with neutral + phase + earth
using a potential-free contact
=> refer to the electrical wiring diagram below
. This function is obtained with electrical logic using a potential-
.
(this function is referred to as heating priority
Incorrect connection of terminals 1-2-0-4-5-6 could result in damage
11
16
A
12
A
10
A
25
A
20
A
16
A
adapted to the type of unit
circuit breaker or switch).
Configuration of supply terminal
Factory-fitted shunt
Attention !
to the regulator and cancellation of the guarantee.
Contactor
Filter pump
Neutral
with a
(see ** below)
.
).