2.4 I Option connection

2.4.1 "Heating priority" option (depending on model)
• This function allows the unit to start the filtration (in 5 minutes cycle every 220 minutes) to detect the water
temperature and thus switch on the filtration + heating unit to maintain this temperature at a constant value. It is
said that the filtration pump is slaved to the heating system. Filtration is maintained or put into operation if the pool
temperature is below the required temperature.
• For the connection, connect the filtration timer to terminals 1 and 2 and add a shunt between terminals 3 and 4.
• Modification of the time between 2 filtration operations (value in number of minutes):
- press
and
or
- press
until the
the
and
keys.
- Once the value has been modified, press
- press
to exit the menu.
2.4.2 "Remote control" option (depending on model)
• This option enables the device's user interface to be duplicated to enable the device to be controlled by remote. To
do so, use the remote control kit available as an accessory.
• For the connection, consult the manual supplied with the kit.
1-
2 : power for the filtration pump power contactor coil
1
: filtration timer
: power contactor (tripolar or bipolar) for the filtration system
2
pump motor
: separate cable for the "heating priority" function
: heat pump terminal (see wiring diagram § "5.3 I Wiring
diagram")
: fuse
at the same time for 3 seconds:
parameter appears, then press
or
appears,
or
to change the parameter using
to confirm,
EN
15