2.3 Hydraulic connections

Follow the hydraulic connection direction (see § «Sizes» in the appendix).
• The connection will use Ø40 piping, or Ø50 using the supplied adapter (see §1.2), use the half-union fittings to connect
to the pool filtering circuit, after the filter and before water treatment.
• Installing a by-pass is mandatory and facilitates operations on the appliance.
• Adjust the water flow using valve VB, and leave valves VE and VS open.
• Make sure the hydraulic fittings are correctly tightened and that there are no leaks.
Condensate drainage: warning, your appliance can release several litres of water per day; it is highly recommended
to connect the drainage to the drains.
Connect an interior Ø15 pipe (not supplied) to the corrugated angle to be fitted under the appliance base
(supplied, see §1.2).

2.4 Electric connections

2.4.1 Voltage and protection
• The appliance is designed for connection to mains electricity using a neutral TT and TNS wiring,
• Electric protection: using a circuit breaker (D curve) or a fuse (Am) (calibre 16A), with a 30 mA ground fault circuit
breaker at the head of the line (circuit breaker or switch).
PW 5M-7M-9M
• connect the power cord supplied with the appliance to a 16A socket complying with the standards and regulations in
force in the country where it is installed,
• extension cords and adapters must not be used,
• If the power supply cable is not long enough, contact a qualified technician.
PW 11
• the electrical supply of the appliance must come from a protection and switching device (not supplied) complying with
the standards and regulations in force in the country,
• the electrical supply cable must not be exposed to elements that are sharp, hot or represent a crush hazard,
• check that all cables are secure and all terminal connections are correct.
Acceptable voltage variation: -10%, +7% (while running).
2.4.2 Connections
• Check the strength of the power supply cable on the connection terminal block
H0357900.D - EN - 2014-03
VE: water intake valve
VB: by-pass valve
VS: water output valve
* minimum distance
PW
Test pressure
bar
Service pressure
bar
Load loss
mCE
Water flow
optimum
m³/h
minimum
Water flow
m³/h
maximum*
* rate not to be exceeded
phase (L) + neutral (N) + Ground (PE)
5M
7M
9M 11M
6
1.5
1
1
1.5
1.5
4
6
8
8
10