EasyLine EL3000 Series Commissioning Instructions
Analyzer(s)
Limas23 with calibration cells
(automatic calibration)
Limas23 without calibration
cells (automatic calibration)
Limas23 without calibration
cells (manual calibration)
Limas23 + Magnos206 or
oxygen sensor with
calibration cells
(automatic calibration, i.e.
Magnos206 with single-point
calibration)
Limas23 + Magnos206 or
oxygen sensor without
calibration cells
(automatic calibration)
Limas23 + Magnos206 or
oxygen sensor without
calibration cells
(manual calibration)
Magnos206
Magnos206 with suppressed
measuring range
Magnos206 with single-point
calibration
Magnos206 with substitute
gas calibration
Magnos27
Magnos27 with substitute gas
calibration
Caldos27
Caldos27 with a
suppressed measuring range
Caldos27 with single-point
calibration
Test gas for the zero-point calibration
and the single-point calibration
N
or air or
2
UV sample component-free gas
N
or air or
2
UV sample component-free gas
N
or air or
2
UV sample component-free gas
N
or oxygen- and
2
UV sample component-free gas
N
or oxygen- and
2
UV sample component-free gas
N
or oxygen- and
2
UV sample component-free gas
Oxygen-free process gas
Test gas with O
concentration near the
2
starting point of the measuring range
Test gas with O
concentration in an
2
existing measuring range or ambient air.
Same moisture content as process gas.
Oxygen-free process gas or substitute
gas (O
in N
)
2
2
Oxygen-free process gas
Oxygen-free process gas or substitute
gas (O
in N
)
2
2
Sample component-free test gas or
process gas
Test gas with a sample component
concentration near the starting point of
the measuring range
Test gas with a known and constant rTC
value (standard gas; possibly also dried
room air)
* Test gas mixture for multiple sample components possible if no cross-
sensitivity is present
Test gas for the end-point
calibration
Calibration cells or
test gas for each sample
component
Test gas for each sample
component
Test gas for each sample
component
Either calibration cells and test
gas for oxygen detector or
test gas for each sample
component, respectively for each
detector
Test gas for each sample
component, respectively for each
detector
Test gas for each sample
component, respectively for each
detector
Process gas with known O
concentration
Test gas with O
concentration
2
near the end point of the
measuring range
Substitute gas, e.g. dried air
Process gas with known O
concentration
Substitute gas, e.g. dried air
Test gas or process gas with a
known sample gas concentration
Test gas with a sample
component concentration near
the end point of the measuring
range
2
2