Other Problems; Dark Lines In Halftone Areas At 75Mm Intervals; Recycled Or Thin Paper Is Severely Curled After Printing; When Fluorescent/ Led Lamps Flicker (Only For 100V Models) - Ricoh SP 330DN Field Service Manual

Machine code: m0c3, m0c4, c0c5, m0c6, m0c7
Hide thumbs Also See for SP 330DN:
Table of Contents

Advertisement

6.Troubleshooting

Other Problems

Dark Lines in Halftone Areas at 75mm Intervals

Using the machine in a room where the humidity is too low may cause dark lines in halftone areas at
75mm intervals. This is because low-humidity conditions tend to cause variations in light sensitivity
across the surface of the drum.
Selecting [On] for [Low Humidity Mode] under [System Settings] (User Tools) may help to prevent these
lines from appearing.
When the low humidity mode setting is enabled, the drum is rotated slightly every 15 minutes. This
keeps the light sensitivity constant across the entire surface of the drum.

Recycled or Thin Paper Is Severely Curled after Printing

If the delivered paper is curled, it cannot be stacked properly. In such a case, raise the paper stopper
on the output tray and remove the paper frequently.
Setting "1" or "2" for [Interval Setting] in the SP menu may help to control the face curl of paper.
(Default: 0 (OFF))
[Interval Setting] is enabled when using normal paper or recycled paper in A4 or LT size.
Four-line LCD panel: SP menu > [Engine Maintenance] > [Interval Setting]
Touch panel: SP menu > [Engine Service Setting] > [Interval Setting]
When setting "1" for [Interval setting], the printing speed becomes half after printing for 1 minute.
When setting "2" for [Interval setting], the printing speed becomes 13ppm. The intervals between sheets
are changed, and the service life of the parts is shortened as shown in the table below.
Normal
When setting "2" for [Interval Setting]

When Fluorescent/ LED Lamps Flicker (Only for 100V Models)

Problem
Under the usage environment of this machine, at the installation location, fluorescent and/or LED lamps
flicker.
Causes
A voltage drop occurs when an electrical current is applied to the fusing lamp. It depends on the
electrical power environment at the customer's installation location.
194
PPM
Interval
(mm)
32
58
10.414
13
402
12.269
Time for 1 job
Service life
(sec)
(K pages)
105
89

Hide quick links: