Sc 6Xx (Communication And Other Errors) - Ricoh SP 330DN Field Service Manual

Machine code: m0c3, m0c4, c0c5, m0c6, m0c7
Hide thumbs Also See for SP 330DN:
Table of Contents

Advertisement

6.Troubleshooting
No.
Type
SC557 B
Zero-crossing frequency exceeded
The number of zero cross signal interrupts do not reach a specified value during
frequency detection.
None
No.
Type
SC559 A
Fuser 3 times jam error
The paper jam counter for the fusing unit reaches 3. The paper jam counter is
cleared if the paper is fed correctly.
This SC is activated only when this function is enabled with "SC559 Detection" in
"Engine Maintenance" (default "OFF").
Turn off this function after a jam removal.
No.
Type
SC580
A
Environment thermistor error
The thermistor output is less than 0°C for 5 seconds after the fusing lamp turns ON.
Disconnected or defective environment thermistor
1.
2.

SC 6xx (Communication and Other Errors)

No.
Type
SC688 D
PRREQ signal not asserted
The print request signal (PRREQ) signal is not asserted within the prescribed time
after paper reaches the registration stand-by position,
1.
2.
178
Error Name/Error Condition/Major Cause/Solution
Unstable frequency of the power supply line
Error Name/Error Condition/Major Cause/Solution
Defective fusing unit
Defective fusing control
Error Name/Error Condition/Major Cause/Solution
Reset the SC.
Replace the environment thermistor.
Error Name/Error Condition/Major Cause/Solution
Main board error
Communication error
Turn the power OFF and ON.
Check the interface harness of the main board.