Hb4596 - LEGRAND 3440 Technical Sheet

Myhome automation
Table of Contents

Advertisement

Switch control RF 1 gang
Description
Radio control device for the control of an ON/OFF or Dimmer actuator or group of
actuators.
When controlling Dimmer actuators, it will only possible to switch the load on/off, but
not to adjust the power level (dimmer function).
Technical data
Power supply:
Duration of the batteries:
Operating temperature:
Technology:
Capacity:
Dimensional data
Size:
2 modules
Configuration
Radio system: "Push and Learn" self-learning type.
Wire system: if the device is integrated in the BUS Automation system using the Gateway
SCS/Zigbee interface it will be possible to manage BUS actuators, which address must be
configured by connecting the configurators to the A, PL, and M housings as indicated.
A = Room
PL = Light Point
M = Operating mode
Configurator in M
Function
0
Cyclical ON/OFF
1
ON timed - 1 minute
2
ON timed - 2 minutes
3
ON timed - 3 minutes
4
ON timed - 4 minutes
5
ON timed - 5 minutes
6
ON timed - 15 minutes
7
ON timed - 30 minutes
8
ON timed - 500 ms
O/I
Cyclical ON/OFF
OFF
OFF control
ON
ON control
PUL
monostable ON/OFF control (key)
34
No. 1 lithium battery 3 V, CR2032 type
5 years
5 – 45 °C
Radio 2.4 GHz standard ZigBee®
150 m free field, 15 m in rooms with
concrete walls
MQ00406-c-EN
078443
0672 35
079143
Front view
1
7
6
PL
A
2
1
7
M
Legend
1. LEARNING key
2. NETWORK key
3. Configurator socket (A,PL)
4. ON/OFF key
5. NETWORK LED
6. LEARNING LED
7. Configurator socket (M)
24/09/2013
663090
HA/HB4596
655101
L/N4596N
2
3
4
5
3
5
6
4