Description
The radio receiver, fitted in the MY HOME burglar-alarm sYStem, allows the use of
devices which transmit radio wave signals (volumetric sensors, perimeter sensors,
technical alarm sensors, radio system remote control, radio remote control for remote
assistance) inside the burglar-alarm system, transferring the radio signal on SCS cable
(item L4669S). The radio receiver will thus be connected to the SCS cable like any burglar-
alarm device and must be configured depending on whether it is used with radio sensors
or remote control.
The connection between receiver and radio sensors or remote control does not need
conductors because each device is supplied by batteries and the information is
transmitted via radio.
NotE: for more information consult the manual supplied with the product.
Technical data
- Power supply from SCS BUS: 27 Vdc
- Max. absorption:
15 mA
- Operating temperature:
5 – 40°C
Dimensional data
Size: 2 modules
Configuration
Z - This configurator assigns the number of the zone it belongs to within the device
group(any free zone in the system).
Configurators 1 - 8 assign the receiver zone within the group of sensors (IR detectors or
interface contacts);
configurator 9 assigns the receiver zone within the group of auxiliary devices (auxiliary
channel interface or relay actuator);
no configurator assigns the receiver zone within the group of activators (activator,
divider, zone expander).
N° - This configurator assigns the progressive receiver number inside the zone attributed.
Configurator 1 identifies the first device, configurator 2 the second and so on up to a
maximum of 9 expander devices for each of the zones.
AUX - This configurator activates the prealarm (with volumetric and/or perimeter
sensors) or technical alarm function (with technical alarm sensors) and assigns an
auxiliary channel (AUX).
NotE: if the system is configured to have technical alarms, prealarms CANNOT be
generated with the system switched off.
Front view
Legend
1 - Operation indication LED;
2 - Reset or programming key.
Rear view
MQ00049-c-EN
28/04/2014

HC4618

HS4618
HD4618
L4618
1
2
Z
No.
Z
AUX
AUX
Clamp for burglar
alarm BUS
Z
AUX
Z
AUX
N4618
NT4618