Ln4587 - LEGRAND 3440 Technical Sheet

Myhome automation
Table of Contents

Advertisement

Actuator RF for technical alarms
Description
Radio actuator device with relay output to be used for the notification of an alarm
through the activation of visual/acoustic indicators, or for the control of a solenoid valve
for the isolation of the water or gas pipes at the entrance of the house.
The actuator is used together with the specific Radio interface for technical alarms,
H/LN4586.
Related items
The actuator is used in conjunction with the specific radio gateway for technical alarms
H4586 (Axolute) and LN4586 (Livinglight).
Technical data
Power supply:
Operating temperature:
Technology:
Capacity:
Power/absorption of the loads driven:
Dimensional data
Size:
2 flush mounted modules
Configuration
"Push and Learn" self-learning type.
Wiring diagram
100 – 240 Vac 50/60 Hz
5 – 45 °C
Radio 2.4 GHz standard ZigBee®
150 m free field, 15 m in rooms with
concrete walls
2500 W (240 Vac)
1250 W (100 Vac)
N
L
MQ00398-b-EN
Front view
5
4
Legend
1. NETWORK LED
2. LEARNING LED
3. Key
4. LEARNING key
5. NETWORK key
05/06/2014
H4587

LN4587

1
2
3
23