Am5786 - LEGRAND 3440 Technical Sheet

Myhome automation
Table of Contents

Advertisement

Keypad activator
Description
This device arms or disarms the system by keying a secret code previously stored in burglar-
alarm systems central units with display, or in three module flush mounted central units.
By pressing two pushbuttons ("o¬" and "P") and entering the secret code, the system can
be disarmed, while at the same time sending a silent alarm (robbery function).
Related articles:
681 86 (White Cover)
684 86 (Titanium Cover)
Indications supplied by the LED and the Buzzer
(sound signalling device)
Event
Green LED
Keying-in
Flashing
Code entering
-
System armed
OFF
System disarmed
ON
Wrong code entered Flashing (5s)
Intrusion alarm
OFF
24 hour alarm
ON/OFF
Technical data
- Power supply from SCS BUS: 27 Vdc
- Max. absorption:
5.5 mA
- Operating temperature:
5 – 40°C
Dimensional data
Size: 2 modules
Configuration
Z
This configurator assigns the number of the appropriate zone (from 1 to 8) in the "group"
of devices (any free zone in the system).
To configure it as belonging to the activator group, no configurator must be connected.
Configurator 9 assigns the device to the "group" of auxiliary devices (Aux channel
interface or Relay actuator).
This configurator assigns the progressive number to the activator within the group.
Configurator 1 identifies the first device, configurator 2 identifies the second, and so
forth, up to a maximum of 9 activators (dividers, expanders or activators).
MOD
The configurator of this location specifies the type of control unit installed in the system.
Central unit used
3486 - 3485/B - LG-573934 - 573935
HC/HD/HS/L/N/NT4601 - 067520
L/N/NT4600/4
NOTE: When used with central units with display, the secret code is the one saved in
the central units themselves (maximum 25 or 50 codes depending on the type of central
unit). If used with the flush mounted central unit, item L/N/NT4600/4, the code must be
programmed in the central unit itself. In this case, up to 29 codes must be saved.
264
5739 44 (White)
5739 45 (Magnesium)
Red LED
Buzzer
-
Active
-
Active
OFF
-
OFF
-
ON
-
ON
-
ON
-
Configurator value
0
1
MQ00026-c-EN
67506
HD4606
HC4606
HS4606
1
4
7
Front view
5
Rear view
Legend
1 - Red LED: alarm status;
2 - Green LED: system status
OFF: ON, ON: OFF;
3 - Configurator socket;
4 - BUS;
5 - Anti-tamper device socket.
Configuration for use with central unit item L/N/NT4600/4
In order for the keypad to operate as activator of the system with three-module central
unit, it will be necessary to first program the code in the central unit itself following the
procedure below:
1. Place the central unit in maintenance mode by moving the back slide switch to the
OFF position;
2. Press P and check that the yellow LED comes on (PROG);
3. Program the remote controls first (see chapter STARTING AND TESTING);
4. Enter "o¬" + the desired 5 digit code;
5. Ensure that a long beep is emitted by the keypad, and that the central unit responds
with a short beep;
6. To memorize further codes, or several keypads with different codes, repeat 4 and 5;
7. Once the last code has been set, press S on the central unit (the yellow PROG LED goes
off) and move the central unit slide switch back to the ON position;
8. Send a pulse signal using the IR remote control;
9. Perform some arming/disarming tests.
Disabling the keypad BUZZER when keys are pressed
Irrespective of the type of central unit installed, the keypad sound can be enabled/
disabled. To do this press key 1 for 5 seconds, until the activator beeps and flashes
quickly twice.
To switch the sound back on repeat the same procedure.