Ln4594 - LEGRAND 3440 Technical Sheet

Myhome automation
Table of Contents

Advertisement

Dimmer RF for ballasts 0-10V 1000W
Description
Actuator for the control of Ballasts for 0-10 V type Fluorescent tube lamps with power
up to 1000 W max , with ON/OFF LED.
Technical data
Power supply:
Operating temperature:
Technology:
Capacity:
concrete walls
Power/absorption of the loads driven:
Voltage
230 Vac
110 Vac
Dimensional data
Size:
2 flush mounted modules
Configuration
"Push and Learn" self-learning type.
Wiring diagram
100 – 240 Vac 50/60 Hz
5 – 45 °C
Radio 2.4 GHz standard ZigBee®
150 m free field, 15 m in rooms with
see following table
Ballast 0 – 10 V
1000 VA
500 VA
+
N
MQ00404-b-EN
Front view
8
7 6
Legend
1. NETWORK key
2. + key: press and release immediately to activate the load at 66% of its power; press
and hold down to increase the power to the maximum value.
3. NETWORK LED
4. LEARNING LED
5. - key: press and release immediately to activate the load at 33% of its power; press
and hold down to decrease the power to the minimum value.
6. Load ON/OFF LED
7. ON/OFF key
8. LEARNING key
Important:
– Connect a load before performing any "scenario" learning
procedure.
– For conventional type transformers, a load with power 60%
higher than their rated power must be connected.
– For the calculation of the controllable power take into account
the efficiency of standard transformers (e.g.: transformer for a 50
W lamp with an efficiency of 0.78 => power actually absorbed
L
by the transformer = 64 VA)
22/04/2014
H4594
573548

LN4594

1
2
3
4
5
29

Hide quick links:

Advertisement

Table of Contents
loading