Rolling shutter management control
Use
Two-module flush-mounted lowered control with 3 pushbuttons and 3 two-colour LEDs
designed to be used ONLY with advanced actuators (flush mounted or DIN module)
specifically intended for rolling shutter management.
Preset function:
In addition to the Monostable and Bistable UP/DOWN operating modes, by pressing the
STOP pushbutton the control gives the possibility of moving the shutter to a specific
position (Preset) saved by the actuator. IT is also possible to set a different position as
required by the user.
The function can only be set with the configuration of "control-actuator" addresses of
the Point-Point type, or with Room, Group, and General controls, after configuring the
reference actuator (position Ar and PLr). For more details see the Configuration chapter
on the following page.
Related items
Actuator item F401, H/LN4661M2 and AM5861M2
Technical data
Power supply from BUS:
Operating power supply with SCS BUS:
Power consumption on standby:
Operating temperature:
Standards, Certifications, and Marks
• EN50090-2-2: Home and building electronic systems (HBES);
• EN50090-2-3: General functional safety requirements for products intended to be
integrated in HBES;
• EN50428: Switches and related accessories for use in home and building electronic
systems (HBES).
Dimensional data
Size: 2 flush mounted modules
174
27 Vdc
18 – 27 Vdc
7 mA max
0 – 40°C
MQ00591-c-EN
Front view
7
6
Rear view
Legend
1. UP LED: orange (green + red) or purple (red + blue) when the shutter is moving up.
Green or blue when the shutter is still or moving down;
2. UP SHUTTER PUSHBUTTON;
3. DOWN SHUTTER PUSHBUTTON;
4. DOWN LED: orange (green + red) or purple (red + blue) when the shutter is moving
down. Green or blue when the shutter is still or moving up;
5. Push&Learn configuration pushbutton and LED brightness adjustment (see page 2);
6. Preset LED: ON orange (green + red) or purple (red + blue), when the shutter is
moving to the saved position (Preset). Flashing during the virtual configuration;
7. STOP button: Press when the shutter is still, to move it to the Preset position. Press
when the shutter is moving, to stop it at the current position;
8. Configurator socket;
9. BUS cable clamp.
09/06/2014
067558
H4660M2
AM5860M2

LN4660M2

1
2
3
5
4
8
9