Ln4590 - LEGRAND 3440 Technical Sheet

Myhome automation
Table of Contents

Advertisement

Switch without neutral 400W
with LEDS status
Description
Actuator for the control of loads with maximum power 400 W, with ON/OFF LED.
For the connection of the device to the load and to the electric system no neutral
conductor is required.
Technical data
Power supply:
Operating temperature:
Technology:
Capacity:
Power/absorption of the loads driven:
Incandescent
Voltage
Halogen lamp
lamp
Voltage
400 W
Max.
230 Vac
60 W
Min.
200 W
Max.
110 Vac
60 W
Min.
Dimensional data
Size:
2 flush mounted modules
Configuration
"Push and Learn" self-learning type.
Wiring diagram
L
100 – 240 Vac 50/60 Hz
5 – 45 °C
Radio 2.4 GHz standard ZigBee®
150 m free field, 15 m in rooms with
concrete walls
see following table
Ferromagnetic
Electronic
transformer
transformer
400 W
400 VA
400 VA
60 W
60 VA
60 VA
200 W
200 VA
200 VA
60 W
60 VA
60 VA
MQ00400-c-EN
663088
665103
Front view
6
Legend
1. NETWORK key
2. NETWORK LED
3. LEARNING LED
4. ON/OFF key
5. Load ON/OFF LED
6. LEARNING key
Important:
– Connect a load before performing any "scenario" learning
procedure.
– For conventional type transformers, a load with power 60%
higher than their rated power must be connected.
– For the calculation of the controllable power take into account
the efficiency of standard transformers (e.g.: transformer for a 50
W lamp with an efficiency of 0.78 => power actually absorbed
by the transformer = 64 VA)
24/09/2013
H4590
0672 31

LN4590

1
2
3
4
5
25