1-4 zone transponder
divider
Description
This device is used to arm, disarm, and separate the zones of the system by placing a
transponder badge (item 3530S and item 3540 previously stored in the central unit) in
front of the zone transponder badge receiver.
When used in an automation system it performs the control function for the management
of scenarios.
By pressing one of the pushbuttons, the corresponding zone is armed/disarmed.
Within four seconds from the last pressure, the separation performed must be confirmed
by moving a transponder saved in the central unit close to the device.
Should this not take place, then the previous condition is automatically restored. Red LEDs
on indicate that the zones are active, whereas red LEDs off show that they are disarmed.
Technical data
- Power supply from SCS BUS: 27 Vdc
- Max. absorption:
15 mA
- Operating temperature:
5 – 40°C
Dimensional data
Size: 2 modules
BURGLAR-ALARM mode:
Since this item belongs to the activator group, it needs to be set up with the number of
the "group" assigned and the progressive number of the devices in the "group". It can also
be programmed to perform Automation functions (scenario management).
See Automation "MY HOME" guide for details.
Z
This configurator assigns the number of the appropriate zone (from 1 to 8) in the "group"
of devices (any free zone in the system). To configure it as belonging to the activator
group, no configurator must be inserted.
N°
This configurator assigns the progressive number within the group of activators.
Configurator 1 identifies the first device, configurator 2 identifies the second, and so
forth, up to a maximum of 9 activators (dividers, expanders or activators).
NOTE: If all 9 permitted devices have already been assigned to the activator group,
it could be possible to assign to configurator Z (zone it belongs to) a value between
1 and 9, taking into account the progressive number.
MOD
It assigns the modes of the audible signals (BEEP) and luminous signals (LED ON)
provided by the divider when controlled by the transponder; it is used as a activators/
disconnector of the "Burglar-alarm" system.
HS4607/4
Front view
Legend
1 - Transponder badge receiver zone;
2 - LED and pushbutton for controlling of zone 2;
3 - LED and pushbutton for controlling of zone 4;
4 - Indication "System ON/OFF";
5 - Alarm warning;
6 - LED and pushbutton for controlling of zone 3;
7 - LED and pushbutton for controlling of zone 1.
Rear view
Central unit
used
3486
3485/B
HD/HC/HS/L/N/
NT4601
L/N/NT4600/1
A/AM5780/1
AUX
Position not configurable for the "Burglar-alarm" function; configure only if it is necessary
to enable the device for Automation functions (management of the scenarios stored in
the unit or scenario module).
MQ00028-c-EN
24/04/2014
HD4607/4
N4607/4
HC4607/4
L4607/4
1
7
6
5
4
Configurator
LED ON
value
none
YES
1
NO
2
YES
3
NO
4
YES
5
NO
6
YES
7
NO
NT4607/4
AM5787/4
2
3
Z
No.
MOD
AUX
Clamp for burglar
alarm BUS
Enabling
BEEP
YES
YES
NO
NO
YES
YES
NO
NO
1
Need help?
Do you have a question about the Bticino HD4607/4 and is the answer not in the manual?
Questions and answers