Flush-mounted 1-relay actuator
Description
Device to control a single load with a built-in electromechanical relay.
Technical data
Power supply via SCS BUS:
Operating power supply with BUS:
Current draw:
Power/Consumption of driven loads:
Incandescent lamps
LED lamps
Compact fluorescent
Halogen lamps
lamps
230 Vac
1380 W
6 A
150 W
Max. 3 lamps
Dissipated power with max. load:
Size: 2 flush-mounted modules
Configuration
If the device is installed in a My Home system it can be configured in two ways:
- PHYSICAL CONFIGURATION, inserting the configurators in position.
- Configuration via MYHOME_Suite software package, downloadable from
www.homesystems-legrandgroup.com.
1.1 Addressing
Address type
Point-to-point
Room
Lighting point
Group
27 Vdc from the BUS
18 – 27 Vdc
16.5 mA
Linear fluorescent lamps
Ferromagnetic
Electronic transformers
transformers
150 W
0.65 A
2 A cosφ 0.5 460 VA
0.9 W
Virtual configuration (MYHOME_Suite) / Physical configuration
1-9
1-9
G1, G2=0-9
MQ00072-e-EN
Front view
Rear view
L
L1
Legend
1. Top button
2. Bottom button
3. LED
4. Configurator socket
5. Power line (max 2x2.5 mm
2
)
6. BUS
For a list of the procedures and their meanings, please refer to the instructions in
this sheet and to the "Function Descriptions" help section in the
MYHOME_Suite software package.
05/06/2014