Alarms And Reporting - Avaya CMC1 Installation, Upgrades And Additions

Table of Contents

Advertisement

Completing Installation and Cable Pinouts

Alarms and Reporting

Resolve Alarms
1. Examine the alarm log. Resolve any alarms using Maintenance for Avaya
MultiVantage DEFINITY Server CSI.
2. Refer to
faults are suspected.
Enable Alarm Origination to INADS
No External Modem Installed (or No Alarm Origination to INADS)
1. Type change system-parameters maintenance and press
2. Type n in the Alarm Origination Activated to OSS Numbers field
and press
3. For some DEFINITY ECS software releases, enable Cleared Alarm
Notification and Restart Notification before the submitting
the form.
External Modem Installed
1. Type change system-parameters maintenance and press
2. Type y in the Alarm Origination Activated to OSS Numbers field
and press
3. For some DEFINITY ECS software releases, enable Cleared Alarm
Notification and Restart Notification before the submitting the
form.
4. Be sure the system is part of the INADS database by calling the INADS
Database Administrator at the Technical Service Center (TSC). Verify that
INADS can dial into the system and that the system can dial out to INADS.
As part of the system registration process, the INADS Database
Administrator enables Alarm Origination and customer options.
2-2
Issue 5 October 2002
''Power Supply LED Indications'' on page 2-8
Enter.
Enter.
NOTE:
When calling from a remote modem, you may need to disable error
correction to allow the modems to connect successfully. For example,
the AT&T Paradyne KeepInTouch
command.
if power supply
Enter
Enter
®
modem may require the "AT\n0"
.
.
555-233-118