Broil Burner And Ignitor - LG LRG30855S Series Training Manual

Table of Contents

Advertisement

BROIL BURNER AND IGNITOR

IMPORTANT!
When replacing the ignitor, the connector end must be positioned OUTSIDE the
range insulation. Do not allow the connector to be inside or next to the insulation.
Allow the rigid over-sleeve to position the connector away from the insulation.
The insulation should be allowed to surround the ignitor lead wires, protecting the
connector from any heat loss at the insulation opening.
GAS RANGE
1.
Remove the oven door.
(Page 18.)
2.
Remove the screw that holds
the burner in place.
3.
Lower the burner.
4.
Remove the two hex head
screws that hold the ignitor to
the burner.
5.
Remove the burner.
NOTE: When reinstalling the burner, be
sure the tab on the burner is inserted
into the slot on the rear wall of the
oven. Make sure the orifice hood is
inserted into the burner inlet opening.
6.
Remove the access cover from
the back of the range and
disconnect the ignitor connector.
7.
Remove the wire retainer and
gently pull the connector through
the oven wall and remove the
ignitor.
Page 26 of 72
TRAINING MANUAL

Advertisement

Table of Contents
loading