Remove the grates, burner caps, and burner heads. Then remove the brass
orifice (spud) in the chimney of each burner using a
driver.
The LP orifices are color coded as well as marked with an L and the orifice size.
RIGHT FRONT
LEFT FRONT
LEFT REAR
RIGHT REAR
CENTER
GAS RANGE
NOTE:
The orifices have spring-loaded
retaining rings around the hex head to
hold the orifice in the nut driver during
installation and removal. A slight
amount of force is required to push the
nut driver down over the ring.
Install the LP orifice spuds into their
correct positions as described as
follows. A mark (I, II, or III) is engraved
on the top of the orifice to denote the
location of the orifice as shown in the
illustration.
The marks appear on both the LP and
Natural Gas orifices. The locations
indicated by the marks are the same
for both gasses.
10,000 BTU Orange/Light Brown
9,500 BTU Blue/Brown
9,100 BTU Orange/Green
5,000 BTU Blue/Blue
5,000 BTU Blue/Blue
Page 44 of 72
9
/
" (7 mm) wrench or nut
32
TRAINING MANUAL