CLEAN and LOCK SEQUENCE

Programming the Clean Cycle:
Press SELF-CLEAN pad. 4 hours and 20 minutes (4:20) appears on the time
display. (Cleaning time can be changed from the 4 hour and 20 minute starting
point by pressing the SELF-CLEAN pad a second time.)
After START has been pressed, the word ON illuminates in red and the word
LOCKED flashes to indicate the cycle has begun.
Locking the Door:
After programming the clean cycle and pressing START pad, the control
energizes the lock relay. Voltage (120 VAC) is applied to the lock motor circuit.
Oven door must be closed before lock motor can run. LOCKED will flash and
control will beep until the door is closed.
The lock motor begins to revolve and turns a cam mounted to the motor shaft.
The word LOCKED will flash on and off on the display while the lock motor is in
motion.
As the cam revolves about ½ revolution (approximately 12 seconds), it has
moved the lock hook into a corresponding slot in the oven door which secures
the door.
The words LOCKED and ON with the clean cycle time remaining will be
displayed.