TESTING BURNER FLAME STABILITY

Test 1
Turn the knob from HI to LOW quickly. If the low flame goes out,
increase the flame size and test again.
Test 2
With the burner on LOW setting, open and close the oven door
quickly. If the flame is extinguished by the air currents created by
the door movement, increase the flame height and test again.
Test 3
With 2 burners on HIGH setting, set a third adjusted burner on
LOW. Turn the first knob from HI to LOW quickly. The third burner
should stay lit.
MANIFOLD PANEL
GAS RANGE
1.
Remove the oven door.
(See page 18.)
2.
Remove the main top.
(See page 21.)
3.
Remove the surface burner valve
knobs by pulling each knob straight
out.
4.
Remove the two ¼" hex head
screws that attach the shield to the
top right side of the manifold panel.
5.
Remove the 2 Phillips-head screws
and the 2 guides from the main top.
6.
Remove the 4 Phillips-head screws
that hold the front of the manifold
panel to the gas manifold.
7.
Remove the three ¼" hex head
screws from the bottom of the
manifold panel.
8.
Pull the manifold panel straight out
from the range.
Page 38 of 72