COMPONENT VOLTAGE TEST MEASUREMENTS

COMPONENT
Oven light
OL to N
Bake ignitor
Bake to N
Broil ignitor
Broil to N
Warming drawer
WD OUT to N
element
Latch motor
MDL to N
Fan motor
GAS F Fan HI to N
high speed
Fan motor
GAS S Fan LO to N Door closed and CONV BAKE
low speed
Surface ignitor
Violet wire
switches
(disconnected from
module) to N
GAS RANGE
TEST LOCATION
Page 69 of 72
CONDITIONS
Door closed and oven light not
selected ON from control
panel
Door open
Door closed and oven light
selected ON from control
panel (relay clicks)
Bake operation initiated (relay
clicks)
Bake not initiated or burner in
cycle OFF status
Broil operation initiated (relay
clicks)
Broil not initiated or burner in
cycle OFF status
Warming drawer operation
initiated (relay clicks)
Warming drawer not initiated
or burner in cycle OFF status
Door closed and clean cycle
initiated (relay clicks)
Door closed and clean cycle
cancelled (relay clicks)
Door open and clean cycle
initiated (relay clicks)
Door closed and CONV BAKE
or CONV BROIL initiated
or CONV BROIL initiated
Rotate knob to LITE position
TRAINING MANUAL
VOLTAGE
120 V
AC
0 V
AC
120 V
AC
120 V
AC
0 V
AC
120 V
AC
0 V
AC
120 V
AC
0 V
AC
120 V
for
AC
10 seconds
(lock door)
120 V
for
AC
10 seconds
(unlock door)
120 V
until
AC
alarm stops
(25 seconds,
then 0 V
)
AC
120 V
AC
(0 V
during
AC
pre-heat)
120 V
AC
(0 V
during
AC
pre-heat)