MANIFOLD BURNER VALVES

The manifold burner valves are located behind the manifold panel. Each valve is
attached to the manifold by a single screw.
GAS RANGE
1.
Turn off the gas supply.
2.
Remove the manifold panel.
(See page 38.)
3.
Using a ½-in. open end wrench,
disconnect the burner inlet tube
from the valve.
4.
Remove the ¼-in. hex-head screw
that holds the valve to the manifold.
5.
Lower the valve from the manifold.
6.
Remove the protective cover from
the valve stem.
7.
Remove the ignitor switch from the
valve. (See page 40.)
WARNING!
Ensure the valve seal and the
screw seal are carefully positioned
before installing the valve.