Performance verification
58
3. Set the oscilloscope settings as follows:
Control
Vertical
Horizontal
Record Length
Acquire menu
Trigger position
Trigger slope
Trigger level
Input impedance
Measure
4. Measure the low and high levels and record the results in the test record.
1 V AC coupled into 75 Ω.
5. On the SPG8000, set the Word Clock output to 1 V (AC):
a. Press the AES button.
b. Press the up (▲) arrow button until you see AES WORD CLOCK
OUTPUT.
c. Press the right (►) arrow button until you see 1 Volt (AC), and then press
the ENTER button.
6. Set the oscilloscope settings as follows:
Control
Vertical
Horizontal
Record Length
Acquire menu
Trigger position
Trigger slope
Trigger level
Input impedance
Measure
7. Measure the level and record the result in the test record.
Setting
500 mV/div
10 μs/div
1000
Sample
50%
Rising Edge
+0.5 V
1 MΩ
Amplitude
Setting
500 mV/div
200 μs/div
1000
Sample
50%
Rising Edge
+0.0 V
1 MΩ
Amplitude