Preparation
Check for Option 3G
SDI diagnostics
SPG8000 Specifications and Performance Verification
Be sure you have performed the performance verification preparation before
proceeding. (See page 19, Performance verification preparation.)
Performance verification procedures can be performed individually, if needed.
Check whether Option 3G is installed on your instrument. If Option 3G is
installed, then you should use the setups in the following procedures that are
called out for Option 3G.
1. Press the SYSTEM button to access the SYSTEM menu.
2. Press the up (▲) or down (▼) arrow button to select SYSTEM : OPTIONS.
The second line of the display lists the installed options. The readout will
show 3G if Option 3G is installed.
Check the SDI diagnostics before performing the performance verification tests.
Some of the SDI diagnostics are available only when the instrument is in factory
mode.
1. Change the instrument to factory mode. (See page 19, Set SPG8000 to
Factory Mode.)
2. Load the factory default preset. (See page 20, Load the factory preset.)
3. Press the SYSTEM button to access the SYSTEM menu.
4. Use the up (▲) or down (▼) arrow button to select SYSTEM :
DIAGNOSTICS, and then press the ENTER button.
5. Use the down (▼) arrow button to view the PLL STATUS MAIN display.
6. Use the right (►) arrow button to view the PLL STATUS SDI display.
7. Check that Flex0 and Flex1 both show Lock, and then record Pass or Fail
in the test record.
8. Use the right (►) arrow button to view the DDS STATUS SDI display.
9. Check that DDS0 Phase and DDS1 Phase both show Lock, and then record
Pass or Fail in the test record.
10. Use the down (▼) arrow button to view the VOLTAGE display.
11. Use the left (◄) arrow button to view the VOLTAGE SDI BRD displays
1 through 4.
12. Check that all voltages show OK for each VOLTAGE SDI BRD display, and
then record Pass or Fail in the test record.