SPG8000 Specifications and Performance Verification
4. Set the reference source on the SPG8000 to internal:
a. Press the REF button. You should see REFERENCE : SOURCE on
the menu.
b. Use the left (◄) or right (►) arrow button to select Internal.
c. Press the ENTER button.
5. Set BLACK 1 to PAL on the SPG8000 as follows:
a. Press the BLACK button. You should see BLACK 1 : FORMAT on
the menu.
b. Use the left (◄) or right (►) arrow button to select PAL.
c. Press the ENTER button.
6. Check that the video monitor shows PAL as the reference input.
7. Record the result in the test record.
8. Set the BLACK 1 output of the SPG8000 under test to 1080 59.94i as follows:
a. Press the BLACK button until you see BLACK 1-3 : HD TRI-LEVEL
SYNC RATE on the menu.
b. Press the right (►) arrow button to select Non-Integer, and then press
the ENTER button.
c. Press the BLACK button until you see BLACK 1 on the menu
d. Press the left (◄) arrow button until 1080 59.94i appears, and then press
the ENTER button.
9. Check that the video monitor shows a 1080 59.94i signal on the reference
input.
10. Record the result in the test record.
11. Set the BLACK 1 output of the SPG8000 under test to 1080 60i as follows:
a. Press the BLACK button until you see BLACK 1-3 : HD TRI-LEVEL
SYNC RATE on the menu.
b. Press the right (►) arrow button to select Integer, and then press the
ENTER button.
c. Press the BLACK button until you see BLACK 1 on the menu
d. Press the left (◄) arrow button until 1080 60i appears, and then press
the ENTER button.
12. Check that the video monitor shows a 1080 60i signal on the reference input.
13. Record the result in the test record.