Tektronix SPG8000 Technical Reference page 51

Master sync / clock reference generator
Hide thumbs Also See for SPG8000:
Table of Contents

Advertisement

SPG8000 Specifications and Performance Verification
1080 24p functional lock and timing.
18. Set the SDI A output format of the reference module to 1080 24p as follows:
a. Press the MODULE button until you see SDI output you are using in
the menu.
b. Press the FORMAT button.
c. Press the left (◄) arrow button until 1080 24p appears, and then press
the ENTER button.
d. Press the BACK button to exit the menu.
19. Set the reference unit BLACK 1 to 1080 24p Tri-level Sync as follows:
a. Press the MODULE button until you see GPS7.
b. Press the down (▼) arrow button to view BLACK 1 on the menu, and
then press ENTER.
c. Press the down (▼) arrow button to view SELECT FORMAT.
d. Press the left (◄) or right (►) arrow button to select 1080 24p, and then
press the ENTER button.
20. Set the reference format of the SPG8000 unit under test to HD Tri-level
Sync as follows:
a. Press the REFERENCE button.
b. You should see SOURCE in the menu. If you do not, press the down
(▼) arrow button until it appears.
c. Press the right (►) arrow button until HD Tri-Level SYNC appears,
and then press the ENTER button.
21. Set the BLACK 1 output of the SPG8000 unit under test to 1080 24p Tri-level
Sync as follows:
a. Press the BLACK button until you see BLACK 1-3 : HD TRI-LEVEL
SYNC RATE on the menu.
b. Press the right (►) arrow button to select Integer, and then press the
ENTER button.
c. Press the BLACK button until you see BLACK 1 on the menu
d. Press the left (◄) arrow button until 1080 24p appears, and then press
the ENTER button.
22. Select the SDI input on the waveform monitor.
Performance verification
37

Advertisement

Table of Contents
loading

Table of Contents