Maintenance and Trouble Clearing
FJTU-320-515-480
3.13
BIP2ERR
Table 3-11: BIP2ERR (BIP2 Error Data Generated)—Standing Condition
AID
Direction
Type
VT1
TRMT
3.14
CANVAL
Table 3-12: CANVAL (CANC-VALTM Command Acceptable)—Transient Condition
AID
Direction
Type
COM
NA
3.15
CLEI-FLT
AID
Direction
Type
EQPT
NA
3.16
CLEI-LBC
Table 3-14: CLEI-LBC (Laser Bias Current Alarm)—Standing Condition
AID
Direction
Type
EQPT
NA
Issue 9, May 1999
Probable Cause
CONN-TSTSIG-VT1 has
been executed.
Probable Cause
NE can now accept cancel
validation timer for
software download (SWDL).
Table 3-13: CLEI-FLT (Plug-In Failure)—Alarm Event
Probable Cause
The plug-in unit has failed.
Probable Cause
The laser diode mounted in
the LC1A card may be bad.
FNC and FNC Customer Use Only
Suggested Corrective Action
• Verify that the facility testing is complete.
• Execute the DISC-TSTSIG-VT1 command.
Suggested Corrective Action
Send CANC-VALTM command to NE if new
software version is accepted by technician.
Suggested Corrective Action
Refer to Section 4, in this practice, or the Table of
Contents, located in the front of this practice, to
select the appropriate unit replacement
procedure.
Suggested Corrective Action
Refer to Section 4, in this practice, or the Table of
Contents, located in the front of this practice, to
select the appropriate unit replacement
procedure.
3.13: BIP2ERR
Vol. ll, Page 480.3-13