Maintenance and Trouble Clearing
FJTU-320-515-480
3.75

TMGSW

These messages indicate a switch in the timing reference:
TMGSW/PRS/STU/ST2/ST3/SIC/ST4/RES/FAIL/NA
Table 3-73: TMGSW (Timing Reference Switch)—Transient Condition
AID
Direction
Type
SYNCIN
NA
3.76

TRCM

Table 3-74: TRCM (Path Trace Mismatch)—Transient Condition
AID
Direction
Type
STS1
TRMT/RCV
Issue 9, May 1999
Probable Cause
A system timing reference
is detected.
Probable Cause
Incoming path
• The provisioning of the near-end expected path trace does
trace label does
not agree with the provisioning of the far-end path trace.
not match
Correct the provisioning that is in error. Do not change
expected path
expected trace based only on the basis of the incoming trace
trace label.
value. This would defeat the purpose of this feature.
• If the path trace value provisioned at the far end is identical
to the provisioned expected trace at the near end, a
mismatch indicates a cross-connect error somewhere in the
path.
• If a cross-connect error is suspected in a ring configuration,
manually switch the channel to the other direction. If the
TRCM clears, check the cross-connects in the suspect
direction.
FNC and FNC Customer Use Only
Suggested Corrective Action
• The TCA-ENH unit is defective.
• Check the upstream ADM for optical channel
unit failure or removal.
• Check the fiber-optic path and perform trouble
analysis as needed.
Suggested Corrective Action
3.75: TMGSW
Vol. ll, Page 480.3-47