Fujitsu FLM 150 ADM Maintenance And Trouble Clearing page 104

Table of Contents

Advertisement

Maintenance and Trouble Clearing
FJTU-320-515-480
Step 5
Repeat trouble analysis procedures (refer to Section 3, Responding to Alarms and
Conditions). Is the LINE LED off and the FAIL/SVCE LED green on the local TSA
unit?
Complete your fault-reporting documentation.
Note: The Hardware Data Record form is provided in Appendix A of the Plug-In Unit
Installation practice, FJTU-320-515-220.
You have completed this procedure.
Issue 9, May 1999
If Yes:
FC9612TSB1
Figure 4-5: TS1A-BSC Unit Front Panel
FNC and FNC Customer Use Only
4.4: Replacing the Time-Slot Assignment (TS1A)
Call the Fujitsu Technical Assistance Center at
1-800-USE-FTAC (1-800-873-3822) for assistance.
FAIL
SVCE
LINE
TS1A
If No:
Vol. ll, Page 480.4-12
Unit