Maintenance and Trouble Clearing
FJTU-320-515-480
c. Use the FE SEL button to step through all the subscribed nodes. Check for
alarm lights on the AW1A at each node.
d. Record the alarm severity displayed on the AW1A unit (CR, MJ, MN) in the
trouble log.
e. If the FE ACT LED is lit, read the identity of the far-end node on the
EQPT NO. display and record the alarm severity displayed on the AW1A
unit for that node in the trouble log. Repeat this process by using the FE
SEL button to step through each subscribed node.
f. Address near-end conditions first, then work on other alarms in the order of
their severity.
Log on the node from which the alarm condition is originating.
Step 2
Press CTRL + X (ACS LED lights on the SV1A unit).
Press CTRL + X (Welcome screen).
Press 3 for TL1.
ACT-USER:TID:UID:CTAG::PID;
TID = FUJITSU
UID = ROOT
PID = ROOT
Step 3
Retrieve all current alarms using TL1 or FLEXR. Record them in the trouble log.
RTRV-ALM-ALL:TID:CTAG;
Issue 9, May 1999
TL1
TL1
FNC and FNC Customer Use Only
1.1: Alarm/Status Identification
FLEXR 7.71
Session
Logon
Click OK (Port Set-Up).
Enter System ID: FUJITSU
Enter User Name: ROOT
Enter Password: ROOT
Click OK.
Repeat for other TIDs.
FLEXR 7.71
Click once in the Alarm window.
Exit.
Vol. ll, Page 480.1-2