Maintenance and Trouble Clearing
FJTU-320-515-480
3.58

RFI-CON

Table 3-56: RFI-CON (Remote Failure Indicator-Connectivity)—Alarm Event
AID Type
Direction
STS1
RCV
150 ADM
DROPPED
SIGNAL
3.59

RFI-PLD

Table 3-57: RFI-PLD (Remote Failure Indicator-Payload Defect)—Alarm Event
AID Type
Direction
STS1
150 ADM
DROPPED
SIGNAL
3.60

RFI-SRV

Table 3-58: RFI-SRV (Remote Failure Indicator-Server)—Alarm Event
AID Type
Direction
STS1
VT1
RCV
150 ADM
DROPPED
SIGNAL
Issue 9, May 1999
Probable Cause
RFI-connectivity
defect received
OC-3/
OC-12
Probable Cause
RFI-payload defect received
RCV
OC-3/
OC-12
Probable Cause
RFI-server defect received
OC-3/
OC-12
FNC and FNC Customer Use Only
Suggested Corrective Action
Verify that connections are secure.
Suggested Corrective Action
Retrieve alarms and correct.
Suggested Corrective Action
Retrieve alarms and correct.