Fujitsu FLM 150 ADM Maintenance And Trouble Clearing page 192

Table of Contents

Advertisement

Maintenance and Trouble Clearing
FJTU-320-515-480
Step 8
Has the mismount cleared?
If Yes:
Go to Step 9.
Step 9
Place the equipment slots back in service.
a. From the Provisioning menu, choose Service State, then choose Change
Equipment State.
b. Click the unit, then click on any nonselectable unit. A dialog box opens.
c. Select In Service.
d. Click OK.
Place the facilities back in service.
Step 10
a. From the Provisioning menu, choose Service State, then choose Change
Facility State.
b. Click the unit, then click on any nonselectable unit. A dialog box opens.
c. Select the appropriate Channel IDs.
d. Select In Service.
e. Click OK.
f. Click Retrieve to verify that the command was completed.
g. Click Close or Cancel.
Step 11
Were any cross-connects deleted in Step 4 that must be reconnected?
Go to Step 12.
Issue 9, May 1999
Call the Fujitsu Technical Assistance Center at
1-800-USE-FTAC (1-800-873-3822) for assistance.
If Yes:
You have completed this procedure.
FNC and FNC Customer Use Only
5.8: Correcting a Mismounted Unit
If No:
If No:
Vol. ll, Page 480.5-30