X11 Digital Out (24 - Bosch Rexroth Rho 4.0 Connectivity Manual

Hide thumbs Also See for Rexroth Rho 4.0:
Table of Contents

Advertisement

5−16
Bosch Rexroth AG
Interface Ports & Connectors
5.9
X11 Digital Out (24 V)
Electric Drives
and Controls
Working range of the digital inputs:
limit value
0-state
UL/V
Max.
5
Min.
−3
max. 100 µs
Switching time:
When a 1-state is created, the green LED of the corresponding input
turns on.
The rho4.0 has 8 digital outputs separated galvanically.
pin series, 8-pin
LEDs:
1
2
3
4
Working range of the digital outputs:
Nominal current (1-Signal)
Voltage drop at 600 mA
Leak current (0-Signal) / with VN340SP
Short-circuit current with overtemperature
Switching time
Measured switching time without load:
D rise−delay time
D disconnect delay time
Measured switching time under 0.5 A load:
D rise−delay time
D disconnect delay time
transition range
IL/mA
UT/V
30
11
ND
5
green, parallel connected
5
6
7
8
48 µs
700 µs
50 µs
135 µs
RhoMotion
1070072365 / 04
1-state
IT/mA
UH/V
IH/mA
30
30
30
2
11
5,0
X11
1
DIG−OUT−0
2
DIG−OUT−1
3
DIG−OUT−2
4
DIG−OUT−3
5
DIG−OUT−4
6
DIG−OUT−5
7
DIG−OUT−6
8
DIG−OUT−7
500 mA
max. 3V
max. 2 mA
max. 2,5 A
max. 300 µs