Bosch Rexroth Rho 4.0 Connectivity Manual page 51

Hide thumbs Also See for Rexroth Rho 4.0:
Table of Contents

Advertisement

1070072365 / 04
RhoMotion
Interface Ports & Connectors
5.4.1
X10s safety relevant signals and 24-V power supply
for digital outputs and PHG
1
2
3
X10s
Real time interface
Connection for READY contacts, Emergency-stop contacts and confir-
mation keys and feeding the 24V power supply for digital outputs and
PHG. Before connecting the Emergency−stop and confirmation key si-
gnals of the PHG2000 to the periphery, read chapter 5.4, X34 PHG2000.
The voltage input is protected against reverse poling and secured with a
5A neutral fuse. The LED H40 is on when the 24-V-power supply is con-
nected and the fuse is all right.
CAUTION
The 24 V are not buffered in case of a power failure.
Weidmüller plug-in terminal, MSTB 1.5, 14-pin (3.5 mm)
Line type:
Ready contact:
Relay characteristic:
4
5
6
7
8
9
10
11
The Ready Relay is designed so that it is opened in the idle state. The
ready contact closes after the rho4.0 startup and opens in the following
cases:
D The 24-V power supply falls below the permissible limit.
D One of the monitored voltages is outside the permissible range.
Electric Drives
and Controls
shield, cross section min. 0,14 mm
two-channel
D breaking capac.0,5 A/30 V
D rise time
D releasing time 3 ms
D bouncing time 2 ms
12
13
14
Bosch Rexroth AG
2
DC
4 ms
X10s
1
RDY2 channel 1
2
RDY2 channel 1
3
RDY2 channel 2
4
RDY2 channel 2
5
24 V
6
GND 24 V
7
Confirmation key channel1
8
Confirmation key channel1
9
Confirmation key channel2
10
Confirmation key channel2
11
Emergency stop channel 1
12
Emergency stop channel 1
13
Emergency stop channel 2
14
Emergency stop channel 2
5−9