Ethernet-Interface - Bosch Rexroth Rho 4.0 Connectivity Manual

Hide thumbs Also See for Rexroth Rho 4.0:
Table of Contents

Advertisement

5−10
Bosch Rexroth AG
Interface Ports & Connectors
5.5

Ethernet-interface

Ethernet
Electric Drives
and Controls
D The temperature of the rho4.0 rises beyond the permissible limit.
D The Ready Watchdog has run out.
D The RESET key has been actuated.
D The software recognizes an error, e.g. wrong machine parameters,
measuring system alarm etc.
network connection
Via the ethernet interface, the rho4.0 can be connected with a ethernet
network.
The ethernet connection is made via a 'Twisted Pair' line with RJ45 con-
nector. The connection conditions are those defined in IEEE 802.3 for
100BaseT:
RJ45, socket, 8pin
Type:
Length of line:
Type of line:
Transmission velocity:
Coding:
Ethernet 100BaseT
max. 100 m
100 Ω. Twisted-Pair cable
max. 10/100 Mbit/s
manchester-coded data transmis-
sion
1
1
8
8
RhoMotion
1070072365 / 04