j 6. If your machine is air cooled, check the
condensers for accumulation of dirt and lint.
Dirty condensers will reduce the efficiency and
capacity of the machine. Condensers should be
cleaned monthly with a soft brush. Never use
screwdrivers or other metal probes to clean
between the fins.
Note: For machines equipped with an air filter,
it will be necessary to vacuum clean the filters
on a monthly schedule.
Caution:
electrical power prior to cleaning the
condenser. Failure to follow this instruction
may result in electrocution.
j 7. If your machine is equipped with an auxiliary
refrigeration system, check the auxiliary
condenser for accumulation of dirt and lint. Dirty
condensers will reduce the refrigeration
capacity of the mix hopper. Condensers must
be cleaned monthly with a soft brush. Never
use screwdrivers or other metal probes to clean
between the fins.
Caution:
electrical power prior to cleaning the
condenser. Failure to follow this instruction
may result in electrocution.
j 8. If your machine is water cooled, check the water
lines for kinks or leaks. Kinks can occur when
the machine is moved back and forth for
cleaning
or
Deteriorated or cracked water lines should be
replaced
only
by
distributor.

The Air/Mix Pump Checklist

j 1. Dispose of o--rings and valve gaskets if they are
worn, torn or fit too loosely. Replace them with
new ones.
j 2. Handle plastic pump parts with care to avoid
nicks and cracks.
j 3. Be sure the air/mix pump is properly attached to
the drive hub, or severe and costly damage may
occur.
Model C706
Always
disconnect
Always
disconnect
maintenance
purposes.
an
authorized
Taylor
Winter Storage
If the place of business is to be closed during the winter
months, it is important to protect the freezer by
following certain precautions, particularly if the
building is subject to freezing conditions.
Disconnect the freezer from the main power source to
prevent possible electrical damage.
On water cooled freezers, disconnect the water
supply. Relieve pressure on the spring in the water
valve. Use air pressure on the outlet side to blow out
any water remaining in the condenser. This is
extremely important. Failure to follow this procedure
may cause severe and costly damage to the
refrigeration system.
Your local Taylor Distributor can perform this winter
storage service for you.
Wrap detachable parts of the freezer such as beater,
blades, drive shaft, and freezer door, and place them
in a protected dry place. Rubber trim parts and gaskets
can
be
protected
moisture--proof paper. All parts should be thoroughly
cleaned of dried mix or lubrication which attract mice
and other vermin.