Heat Mode Symbol

When the HEAT MODE symbol
the freezer is in the process of a heat cycle. The
heat mode symbol may be selected to start a heat
cycle following a freezer soft lock condition.
For some models, the heat symbol can be selected
to manually start a heat cycle at any time.
Brush Clean Countdown - Displays the number of
days before the next brush cleaning is required.
When the display has counted down to "1", the
machine must be disassembled and brush cleaned
within 24 hours.

Reset Mechanism

The reset button is located in the service panel at
the rear of the machine. (See Figure 20.) It protects
the beater motor from an overload condition. Should
an overload occur, the reset mechanism will trip. To
properly reset the freezer place the power switch in
the OFF position. Press the reset button firmly. Turn
the power switch to the ON position. Touch the
WASH symbol
and observe the freezer's
performance. (See Figure 20.)
Figure 20
WARNING: Do not use metal objects to
press the reset button. Failure to comply may
result in severe personal injury or death.
091002
Important: To the Operator
If the beater motor is turning properly, touch the
WASH symbol
AUTO symbol
freezer shuts down again, contact your authorized
is illuminated,
service technician.

Air/Mix Pump Reset Mechanism

The reset button for the pump is located in the
service panel at the rear of the machine. (See
Figure 20.) The reset protects the pump from an
overload condition. Should an overload occur, the
reset mechanism will trip. To reset the pump, press
the reset button firmly.
press the reset button. Failure to comply may
result in severe personal injury or death.

Adjustable Draw Handle

This unit features an adjustable draw handle to
provide the best portion control, giving a better,
consistent quality to your product and controlling
costs. The draw handle should be adjusted to
provide a flow rate of 5 to 7-1/2 oz. (142 to 213 g.)
of product by weight per 10 seconds. To INCREASE
the flow rate, tighten the screw. To DECREASE the
flow rate, loosen the screw. After setting the flow
rate, tighten the jam nut to secure the adjustment
screw. (See Figure 21.)
32
to cancel the cycle. Touch the
to resume normal operation. If the
WARNING: Do not use metal objects to
Figure 21
Model C606