Avaya IX Room Systems XT Series Release Notes page 26

Table of Contents

Advertisement

© 2019 Avaya Inc. All rights reserved
IOT
Release Notes for Avaya XT Series
Audio transmission/reception
could be choppy when using
RVXT5000-615
USB headset connected to
upper USB port.
Sometimes the system is turned
on, but the camera image is not
QC#25198
present. This is more frequent
using the XT camera switch, for
the first camera.
Issue with an input of XT camera
QC#24231
switch due to noise on this input
in no video signal conditions.
The information about the
HD1/HD2 cameras or audio
XT7000 Series
inputs are available only for the
last selected HD1/HD2 input
[XT4300] When upgrading to
this version, Flex camera presets
RVXT5000-1202
assigned using 8.3.2.56 are lost
and must be configured again.
When connecting different
model camera in daisy chain
there could be some
configuration trouble about
video input format.
In local presentation mode, the
XT7100 endpoint can capture 4K
and 1600x1200 resolutions from
its HD1 input (when configured
to be used for presentation).
HD1 as
When not in local presentation
presentation on
mode, 4K input is downscaled at
XT7000
1080p, while 1600x1200 is
downscaled to 800x600. Please
note that the signal format
connected to HD1 must be
YCbCr 422 for any resolution
higher than 1080p.
IPO 9.1 and 10.0 require Third
SR 1-11610561268
Party license for Avaya XT4300,
XT7100 and XTE240 endpoints
When registered to IPO 10.0,
Avaya XT7100, XTE240 and
IPOFFICE-109632
XT4300 endpoints do not
receive presentation
Cisco SX80 TC7.2.0 is not able to
receive SIP TLS incoming calls if
XT is configured with AES256.
The XT doesn't display the
QC#26789
message to be in call hold when
JIRA-57114
Flare iPad is put in hold
Using Polycom MGC50 (v
QC#2766
8.0.2.6) sometimes H.239
presentation does not function.
Polycom diagnostics incorrectly
QC#2981
identifies XT Series systems.
Incident #16384-10505: Remote
camera switch from HDX to
QC#11493
XT5000 and reverse is not
performed. Issue reported to
Polycom.
Cisco C20 cannot control the
QC#2964
XT5000 camera in H.323 calls.
Polycom MGC systems (v9.0): XT
Series does not receive the
video stream when it is
QC#6665
connected to MGC with default
settings (reference Pivotal
#16384-7589).
Connect USB headset to lower USB port.
Unplug and then pug again the Camera power
connector or use a Flex/Deluxe camera.
Disable unused video inputs on the XT
Select the HD1 or HD2 input to see its diagnostic
info.
To speed up PTZ to camera presets with XT Flex
Camera a brand-new approach has been
implemented since 8.3 FP2. This new
implementation significantly improves customer
experience. Please note that when updating to such
new firmware version all previously set presets will
be lost and must be re-configured.
To avoid any trouble, configure right driver for any
camera, then turn off the system, connect cables
according to the configuration and then turn on the
system.
Use a 3rd Party SIP License to register that XT
Endpoint as a SIP device to an IP Office system
Configure IPO 10.0 with "MediaSecurity=None" to
the extensions associated to those endpoints to
enable presentation towards them.
Disable AES256 on XT or place outgoing call from
Cisco to XT.
For low bit rate calls (up to 256Kbits), set the
maximum call rate of the XT5000 to 2M (the same
max. rate as MGC) in the Administrator Settings >
Call Preferences page.
For 384Kbit- 2Mbit calls: In the MGC Advanced
Properties page, deselect Auto Video Bit Rate.
Known Issues | 26

Advertisement

Table of Contents
loading

Table of Contents