5.4

BATTERY CHARGER SERVICE

PIDs prior to RG2059 are equipped with a battery charger mounted on the generator. If so equipped, when replac-
ing the battery charger ensure the cables are NOT touching anything to prevent the wire chaffing with the following:
1. It is critical to maintain a 20° (+ 5 degrees) angle on the harness clamp. Refer to item b in
2. The positive and negative battery cables must be at a minimum distance, 0.25 in. (6.4 mm) from the battery
charger and the battery charger mounting bracket. Refer to item a in
3. The harness must be at a minimum distance of 0.25 in. (6.4 mm) from the edges as shown in the

Figure 5.3 Battery Cable / Harness Clamp (PIDs prior to RG2059)

T-361
a)
Battery cables must be 0.25 in (6.4mm) from
Battery Charger & Mounting Bracket
Figure
5–2
Figure
5.3.
5.3.
Figure
b)
20° + 5°
5.4.