Auto Re-Start Option; Table 4-9 Auto Re-Start Option - Carrier RG2059 Series Operation And Service

Generator set units
Table of Contents

Advertisement

Condition
Mechanical Noise
Generator
frame
produces
shock when touched
4.4

AUTO RE-START OPTION

Condition
When the Ignition switch is
placed in the RUN position,
nothing happens− no lights
illuminate
Alarm sounds, but engine does
not crank
Engine starts, but the starter
does not disengage
Engine starts, but shuts down
from over speed
Engine cranks, but will not start Electronic Governor Module (EG) is bad
Engine starts, but shuts down
on low oil
Engine starts, but shuts down
on high water temperature
T-361
Table 4–8 Alternating Current Generator
Possible Cause
Bad bearing
Rotor rubbing on stator
Loose laminations
Loose or misaligned coupling
Static charge
Table 4–9 Auto Re-Start Option
Possible Cause
Wait 30 seconds for intake heater to be
activated
Relay defective
Ignition switch defective
3 amp Fuse is bad
Loose connector on module
Auto restart module is bad
Mis-wired connectors
No voltage at Pin 2 of the connector
Check Starter Solenoid
Auto restart module is bad
Speed Sensor wiring loose
Speed Sensor is bad
Auto restart module is bad
Electronic Governor Module (EG) is bad
Section 4.1.1
Section 4.1.2
Section 4.1.6
4–6
Remedy/Reference Section
Replace
Replace
Replace
Check drive gear
Check ground to frame
Remedy/Reference Section
Wait
Check/Replace
Check/Replace Switch
Check and Replace Fuse
Tighten connector
Check for 12 volts at Pin 4/Replace
module
Check/Correct wiring
Trace/Correct
Section 4.1.1
Replace module
Check/Correct
Replace
Replace module
Replace
Replace
Section 4.1.1
Section 4.1.2
Section 4.1.6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rg2100 series69rg15

Table of Contents