6. Troubleshooting

Following are a few common problems that may occur during operation. Here are some suggestions for
easy troubleshooting:
Problem
The unit does not work,
no light.
The unit does not
respond properly to the
DMX control.

7. Fixture Cleaning

The cleaning must be carried out periodically to optimize light output. Cleaning frequency depends on
the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause
greater accumulation of dirt on the unit's optics.
 Clean with soft cloth using normal glass cleaning fluid.
 Always dry the parts carefully.
Clean the external optics at least every 30 days.
Possible Cause
Incorrect power cable
connection.
Incorrect mains voltage.
Incorrect DMX cable
connection.
Incorrect address
assignment to the units.
Unfinished data
connection.
It has been set up an
operating mode different
from the DMX mode
used.
19B
Action
Check the connection of
power.
Measure the mains
voltage
on the main connector.
Check DMX connectors
and cables to see if link
properly. Repair or
replace damaged wires.
Check the addresses of
the units and the protocol
settings.
Insert a terminal plug in
the output jack of the last
unit of the connection.
Check the operating
mode set up.
Try to use another DMX
controller.