Electric grease jockey automatic lubrication system
Hide thumbs Also See for 24Z764:
Table of Contents

Advertisement

Pump
Illuminated Remote Run Button
Available on DMS enabled models only.
Parts:
25C981 - 12VDC
25C982 - 24 VDC
Ref Part No.
51
Push button
52
Connector
53
Button Label
54
O-ring
55
129336 Cab Information Label
55
54
53
F
. 14
IG
Installation
Install the remote run button in an easily accessible
location inside the truck cab.
1. Drill a hole in the panel. (See the
illustration on the right for cutout
dimension. The maximum panel
thickness is 0.472 in./12.0 mm).
2. Remove the lock nut (51a) from
the push button (51). Install the
o-ring (54) (F
. 15).
IG
51
F
. 15
IG
16
Description
51
0.748" [19.0 mm]
54
51a
3. Insert the push button (51) through the hole drilled
through the panel in Step 1. Hand tighten the lock
nut (1a) to secure the push button in place (F
4. Clean the surface around the outer edge of the push
button (1). Position label (53) around the button and
adhere label (F
Qty
1
51
4
1
1
1
52
F
. 16
IG
5. Clean the an area close to the push button for
mounting the label (55) inside cab. Adhere label to
mounting surface.
6. Connect the wiring connector (52) to the push
button and the pump. See Pin and Related Wire
Color Table (below) and Wiring information shown in
F
. 17, page 17.
IG
Pin and Related Wire Color (F
Pin
Pin Name
1
Not Used
2
3
4
5
Manual Run Switch
6
Not Used
7
. 16).
IG
53
. 17)
IG
Color
Not Used
-VDC
Black
+VDC
LED+
White
Orange
Not Used
LED-
Green
. 15).
IG
55
Red
3A5082G