A 1.2 MS-SL interface cable wiring sizes 400...710 kW

Fit the ADV200 MASTER and SLAVE inverters inside the electrical panel. Connect
all the power section cables and connect the signal cable for interfacing between
the 2 drives.
The cable (code 8S860B) for connecting 2 drives is one metre long and has two
quick coupling male MDR connectors at the ends.
ADV-...-MS-..
J4 connector
Wiring instructions:
1.
2.
3.
4.
5.
ADV-...-SL
Connect one of the 2 ends of the interface cable to the XSL connector of the
INT-P-ADV-SLAVE card.
Secure the cable using the specifi c clamp.
Connect the other end of the cable to connector J4 of the INT-SLAVE card
mounted on the INT-P-ADV-MASTER card of the MASTER drive.
Secure the cable in the relative clamp
To prevent the interface cable from coming into contact with the power termi-
nals, fold the excess length of cable inside the SLAVE drive as shown in the
fi gure and secure it using the specifi c cable clamps.
ADV200 • Quick start up guide - Specification and installation
1.
2.
3.
4.
XSL connector
5.
167