10 - Specifi cation
10.1 Environmental Conditions
Installation location __________________Pollution degree 2 or lower (free from direct sunligth, vi-
Installation altitude __________________Max 2000m (6562 feet) above sea level;.
Mechanical conditions for installation ___Vibrational stress: EN 60721-3-3 Class 3M1
Operating temperature ______________-10...+40°C (32°...104°F)
Operating temperature (1) ____________+40 ... +50°C with derating, (+104 ... +122°F with
Air humidity (operating) ______________5 % to 85 % and 1 g/m
Air pressure (operating) [kPa] __________86 to 106 (class 3K3 as per EN50178)
(1)
The drive is suitable for use under the environmental service conditions (climate,
mechanical, pollution, etc.) defi ned as usual service conditions according to
EN61800-2.
Attention
10.2 Standards
Climatic conditions __________________EN 60721-3-3
Electrical safety ____________________EN 50178, EN 61800-5-1, UL508C, UL840 degree of
Vibration __________________________EN 60068-2-6, test Fc.
EMC compatibility ___________________EN61800-3
Protection degree ___________________IP20, ≥ size 7: IP00
Approvals _________________________
10.3 Accuracy
10.3.1 Current control
Loop sampling time ___________________125μs
Response time ______________________600 - 1600μs
PWM frequency _____________________2, 4, 6, 8, 10, 12 kHz (size dependent)
10.3.2 Speed control
Loop sampling time ___________________125μs
Response time ______________________5 - 10ms
Speed measurement __________________FP, F mode
Speed regulation accuracy _____________FOC with Speed feedback : 0.01 % rated speed
136
In menu 4 - DRIVE CONFIG set the Ambient temperature parameter, PAR 564, to 1 (50°C).
10 % derating of output current.
ADV200 • Quick start up guide - Specification and installation
bration, dust, corrosive or inflammable gases, fog, vapour
oil and dripped water, avoid saline environment)
derating)
to 25 g/m
3
condensation or icing (class 3K3 as per EN50178)
pollution 2
L
,
FOC open loop : ± 30 % rated slip
V/F : ± 60 % rated slip