Technical Specifications; Technical Specifications Overview; Technical Data For Simotion P350-3 - Siemens SIMOTION P350-3 Manual

Table of Contents

Advertisement

Technical specifications

7.1

Technical specifications overview

The "Technical data" section contains both a table listing the technical data for the
SIMOTION P complete system and cross-references to the subsections containing the
technical data for the individual components.
7.2

Technical data for SIMOTION P350-3

Technical data
Order numbers
Dimensions
(W x H x D) in mm
Weight
Supply voltage
Input current
Transient voltage interruption
Max. power consumption
Max. current output
Noise emission
Degree of protection to EN 60529
Safety
Protection class
Safety regulations
Electromagnetic compatibility (EMC)
Emitted interference
Noise immunity:
Mains borne disturbance variables on
supply lines
Noise immunity on signal lines
SIMOTION P350-3 and Panels
Manual, 05/2009
6AU1350-3AK4x-
Without DVD: 297 x 267 x 80
With DVD: 297 x 267 x 100
Approximately. 7 kg
24 V DC (20.4 V DC to 28.8 V DC)
Continuous current up to 9 A (up to 14 A for 30 ms on
start-up)
max. 3 ms (at 20.4 V to 28.8 V)
(min. recovery time 10 s)
190 W
+ 5 V/16.5 A
(18.5 W peak)
*
+ 3.3 V/8.5 A
*
a total of 90 W is permitted
*
+ 12 V/6.5 A (8 A peak)
– 12 V/0.3 A
The total power of all voltages is a maximum of 150 W.
< 55 dB(A) according to EN 60034-9
IP20
Protection class (PELV) according to EN 61800-5-1
DC: EN 61131-2; UL508; CSA C22.2 No 142
EN 61800-3 Class C3
± 2 kV; (burst)
± 1 kV; (surge sym.)
± 2 kV; (surge asym.)
± 1 kV; (burst, length < 5 m)
± 2 kV; (burst, length > 5 m)
± 2 kV; (surge, length > 30 m)
7
105