Chapter 2 Preparations
2. Fit the square-shaped protrusions of outer rail
to the square holes of a 19-inch rack. Make
sure that it makes a clicking sound indicating
that it is locked.
The image on the right shows the front left
side of the rack. Install to the rear left side
and front and rear right sides following the
same procedure.
Make sure that the rail is installed at the same
height as the other rail already installed.
Installation/Removal the Server
Important
Confirm that the rail are securely locked so that they will not fall off.
Tips
Although the rail assembly may be somewhat unsteady, it is not defective.
Be sure to observe the following precautions to use the server safely. Failure to
observe the precautions may cause burns, injury, and property damage. For
details, refer to Safety precautions in Precautions for Use.
Do not attempt to lift the server with a single person.
Do not drop.
Do not leave the server being pulled out.
Do not install with the cover removed.
Do not get your fingers caught.
Express5800/R120e-1E User's Guide
CAUTION
2. Installation and Connection
129