ALARM
The display shows the wording:
"E04 + Ith CMP"
The display shows the wording
"E06 + P MAX"
The display shows the wording
"E07 + P MIN"
The following alarm appears on the
display
"E05 + T MAX"
(Max heating temperature alarm)
The display shows the wording
"E08 + INVERTER"
The display shows the wording
"E02 + ITH PUMP"
The display shows the wording
"E01 + OPEN"
THIS MANUAL IS THE PROPERTY OF
Tab. 7.1 Alarm signals
CAUSE
Excessive absorption of the
compressor motor
1. Exceeding of max pressure in the
refrigerator system and intervention of
pressure switch to interrupt the cooling
water flow: the machine functioning is
interrupted for at least 30 sec
2. Faulty pressure switch functioning
1. Exceeding of min pressure in the
refrigerator system and intervention of
pressure switch due to lack of gas in
system or faulty solenoid valve: the
machine functioning is permanently
interrupted until the work conditions
are reset
2. Faulty pressure switch functioning
1. No glycol in the system
2. Faulty heaters functioning
3. Faulty safety thermostat
Intervention of defect relay of the stirrer
inverter due to:
- excessive motor absorption
- one power supply phase to motor
missing
Intervention of the pump thermal relay
due to:
1. excessive motor absorption
2. mechanical block of impeller
Failed tank lid closure
TECHNOGEL SpA
ALL REPRODUCTIONS, EVEN PARTIAL, ARE FORBIDDEN
37
Page 37 of 52
SOLUTION
Contact the Technical Assistance
1. Check water tap opening
Check the water supply line is not
obstructed. The machine restarts
normal functioning upon water flow
restoration
2. Contact the Technical Assistance
1. Contact the Technical Assistance
2. Contact the Technical Assistance
1.Contact the Technical Assistance
2.Contact the Technical Assistance
3.Contact the Technical Assistance
Check there is nothing preventing
stirrer rotation (turning it by hand); wait
a few minutes then power the machine
again
Call the Technical Assistance if the
problem persists
1.Reset the acoustic alarm by pressing
ENTER, wait a few minutes, then press
ENTER again and restart the machine.
2.Remove the causes of the block.
Call the Technical Assistance if the
problem persists
Close the lid