Technogel Mixpasto 60 Use And Maintenance Instructions page 21

Table of Contents

Advertisement

The following screen appears for setting:
-
the TEMPERATURE if the step is a RAMP
-
the TIME if the STEP is a STOP
The temperature can vary between 4°C and 90°C.
The maintenance time of the STOP is defined in HOURS (max 9 hours)
and MINUTES.
Change from HOURS to MINUTES using the LEFT ARROWS.
The parameters are selected using the RIGHT ARROWS.
Press ENTER to go back to T STOP / T RAMP.
Select the SPEED using the LEFT ARROWS.
This enables defining the stirrer speed during the step in question.
Vary the speed expressed in rpm using the RIGHT ARROWS: the
program enables choosing the value from those pre-set in the program.
Use the LEFT ARROW to select FORWARD and then ENTER. This
acquires data from STEP 1.
The STEP2 screen appears: proceed with its setting by means of the
same methods described for STEP1.
This for all 6 STEPS of the chosen program.
The preservation process is automatically activated by the machine, after
the step 6.
Note: the program acquires the default values for the non-set steps that
might be inconsistent with those set by the operator, if data is not set for
all 6 STEPS.
The END screen appears after STEP6: the cursor is on ESC and the
main menu is accessed by pressing ENTER.